SAF-T-LOK CHEMICAL CORP -- PRIMER -- 8010-00N048904
===================== Product Identification =====================
Product ID:PRIMER
MSDS Date:09/05/1990
FSC:8010
NIIN:00N048904
=== Responsible Party ===
Company Name:SAF-T-LOK CHEMICAL CORP
Address:300 EISENHOWER LANE N
City:LOMBARD
State:IL
ZIP:60148
Country:US
Info Phone Num:708-978-2001
Emergency Phone Num:708-978-2001
CAGE:4Z400
=== Contractor Identification ===
Company Name:SAF-T-LOK CHEMICAL CORPORATION
Address:300 EISENHOWER LANE NORTH
City:LOMBARD
State:IL
ZIP:60148
Country:US
Phone:708-971-2001
CAGE:4Z400
============= Composition/Information on Ingredients =============
Ingred Name:ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 91%
OSHA PEL:350 PPM;450 STEL
ACGIH TLV:350 PPM;450 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EXCESS INHAL OF VAPS CAN CAUSE
NASAL & RESP IRRIT. SIGNS/SYMPS OF EXPOS: INHAL:DIZZ, WEAK, NAUS,
HDCH, POSS UNCON. CONT W/EYES: CAN CAUSE SEV IRRIT, RED, TEAR,
BLURRED VISION. SKIN: PRLNGD/RPTD CONT CAN CAUSE IRRIT & DERM.
INGEST: GI IRRIT, NAUS, VOMIT. CHLOROCARBON MATERIALS HAVE PRDCD
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS AND COULD HAVE A SIMILAR EFT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT
FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE KNOWN/DERMATITIS.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR, IF BRTHG HAS STOPPED, GIVE ARTF
RESP & GET MED ATTN. DO NOT GIVE STIMULANTS. EYE: FLUSH W/WATER FOR
@ LST 15 MIN. SEE PHYS. INGEST: DO NOT INDUCE VOMIT, CALL PHYS.
SKIN: WA SH W/SOAP & WATER.
===================== Fire Fighting Measures =====================
Flash Point Method:SCC
Flash Point:>212F,>100C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . WATER MAY BE USED TO KEEP FIRE
EXPOSED CONTRS COOL UNTIL FIRE IS OUT.
Unusual Fire/Explosion Hazard:NEVER USE WELDING/CUTTING TORCH ON CONTR,
BECAUSE PROD CAN IGNITE. ON BURNING PROD GIVES OFF HYDROGEN
CHLORIDE AND TRACES OF PHOSGENE AND CHLORINE.
================== Accidental Release Measures ==================
Spill Release Procedures:PROVIDE ADEQUATE VENTILATION. SOAK UP WITH
SAND, CLAY, EARTH/OTHER ABSORBENT MATERIAL AND SHOVEL INTO
CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT USE IN POORLY VENTD/CONFINED
SPACES. KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. STORE IN A
COOL PLACE AWAY FROM HEAT AND FLAME.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF TLV IS EXCEEDED, AN NIOSH/MSHA APPROVED AIR
SUPPLIED RESPIRATOR IS ADVISED.
Ventilation:LOCAL EXHAUST: YES. MECHANICAL (GENERAL): IF NEEDED.
Protective Gloves:POLYETHYLENE/POLYVINYL ALCOHOL.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN.
Work Hygienic Practices:AVOID PROLONGED BREATHING OF VAPORS OR CONTACT
W/EYES. DO NO TAKE INTERNALLY.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:T4
Boiling Pt:B.P. Text:165F,74C
Vapor Pres:100@68F
Vapor Density:4.5
Spec Gravity:>1(H*2O=1)
Evaporation Rate & Reference:0.4(BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:GREEN LIQUID
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH WATER, REACTIVE METALS, AND CAUSTIC SODA.
Stability Condition to Avoid:OPEN FLAMES, WELDING ARCS, RESISTANCE
HEATERS.
Hazardous Decomposition Products:THERMAL DECOMPOSITION RELEASES
HYDROGEN CHLORIDE AND SMALL AMOUNTS OF PHOSGENE AND CHLORINE.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONTAMD ABSORB MAY BE DEPOSITED IN A LANDFILL
I/A/W LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.